How and where to use guide

VELUX Twin and Combination Flashings 94x160cm EKL PK10 S0222

Suitable applications and roof types

These flashings are designed for pitched roofs with slopes between 30° and 60°. They are commonly used to weatherproof roof penetrations such as windows, vents, or other openings where a secure seal against wind-driven rain and snow is critical. The flashings are compatible with timber structural grades F16, F24, and F36, covering most domestic and light commercial roofing projects. They perform well in exposed locations subject to severe weather exposure.

  • Pitched roofs only: 30–60° slope range
  • Timber grades F16, F24, F36 compatible
  • Roof penetrations: windows, vents, and similar openings
  • Exposed and harsh weather locations

Installation and positioning

Position the flashing so that the upper edge sits under the roof covering above the penetration and the lower edge sits over the roof covering below. Ensure the flashing is centred on the penetration opening and aligned square to the roof pitch. The 94cm length and 160cm width accommodate standard roof penetration sizes. Secure the flashing firmly to the timber framing using appropriate fixings, ensuring no gaps remain between the flashing and the roof surface. Pay particular attention to sealing the upper edge where water run-off is heaviest.

  • Upper edge under roof covering, lower edge over roof covering
  • Centre and square the flashing to the penetration
  • Secure firmly to timber framing with appropriate fixings
  • Seal all edges to prevent water ingress

Limitations and roof pitch requirements

These flashings are engineered specifically for roof pitches between 30° and 60°. Do not use on roofs outside this pitch range, as the flashing design and water shedding performance are optimised for this slope. Steeper pitches may cause water to run off too quickly without proper sealing, whilst shallower pitches risk water pooling and penetration. Always verify your roof pitch before installation. The vinyl-coated polyester material is durable but should not be subjected to mechanical damage during handling or installation.

  • Roof pitch must be 30–60°: do not use outside this range
  • Verify pitch angle before installation
  • Avoid mechanical damage during handling and fitting
  • Not suitable for flat or low-pitch roofs

Maintenance and on-site care

After installation, inspect the flashing regularly to ensure all seals remain intact and no debris has accumulated around the penetration. The vinyl-coated polyester finish is designed to withstand harsh weather without degradation, but check for any cracks, splits, or separation from the roof surface, particularly after severe storms or heavy snow loading. Keep gutters and roof surfaces clear of leaves and debris to prevent water damming. If damage is detected, repair or replace the flashing promptly to maintain weathertightness. Store flashings flat and protected from weather before installation.

  • Inspect seals and edges regularly for damage or separation
  • Clear debris and leaves from roof surface and gutters
  • Check after severe weather or heavy snow loading
  • Repair or replace damaged sections immediately
  • Store flat and protected before installation